Moderated newsgroup PARTS RECYCLING for somebody LOOKING OR SELLING....   >   Metal Working Machine   >   Riveter   >   Out of Area   >   Ttc acterna fireberd 4000 analyzer with option 4005

Ttc acterna fireberd 4000 analyzer with option 4005


What is for sale: Ttc acterna fireberd 4000 analyzer with option 4005

» Recognized As Power Seller of the Month
» Add Us To Your Favorite Sellers
TTC ACTERNA FIREBERD ANALYZER WITH OPTION 4005
Note: System includes installed option 4005 Frequency Synthesize
The FIREBERD 4000 Communications Analyzer is a flexible, cost-effective instrument that tests digital circuits and equipment. Combining convenience and reliable performance, the FIREBERD 4000 is ideally suited for a wide variety of test applications.
Operating at rates from 50 b/s to 15 Mb/s, the FIREBERD 4000 provides a high degree of flexibility for testing G.703, T-Carrier, and DDS circuits, evaluating equipment performance, or performing long-term or unattended testing. THe instrument features a range of standard data rates, plus the ability to operate at non-standard data rates when the optional frequency synthesize is installed.
Synchronous: 50 b/s to 15 Mb/s.
Asynchronous: 50 b/s to 20 kb/s (Internal RS-232/V.24 and MIL-188C interfaces only).
Clock Sources: Fixed internal frequencies, data interface and external BNC.
Internal Clock Frequencies: 300 Hz, 1.2 kHz, 2.4 kHz, 4.8 kHz, 9.6 kHz, 19.2 kHz, 56 kHz, 64 kHz, 128 kHz, 256 kHz, 512 kHz, 1544 kHz, and 2048 kHz +/- 5ppm.
Fixed Patterns: Mar, Space, 1:1, 1:7, 3-in-24, and a user-programmable pattern of 3 to 24 bits in length.
Pseudorandom Patterns: 63, 511, 2047, 215-1, 220-1, 223-1, QRSS.
Messages: Non Programmable: standard FOX asynchronous message in four different code levels; Programmable: three asynchronous messages up to 2000 bytes in length.
Asynchronous Setup: Odd, none, or even parity; 5- to 8-bit code levels; 1, 1.5, or 2 stop bits.
Error Insertion: Single error or fixed 10-3 rate in generated data only.
Sync Loss Thresholds: User-Selectable 100/1000, 250/1000, and 20,000/100,000 errors/total bits.
Block Lengths: 102 to 106 bits, or pattern lengths.
Frequency Measurement Range: 50 Hz to 16 MHz.
Summary Results (Non-Zero results only): Bit errors, bipolar violations (BPVs), character errors, code errors, cylic redundancy check (CRC) errors, block errors, frame errors, frame alignmen signal (FAS) errors, pattern slips, pattern loss.
Error Results: Average bit error rate, average block error rate, bit errors, bit error rate, blocks, block errors, character errors, pattern loss, pattern slips.
Interface-Specific Results: Average bipolar violation rate, average code error rate, average CRC error rate, average FAS error rate, BPVs, BPV rate, code error rate, code errors, CRC errors, FAS errors, frame errors, one-second CRC error count.
Signal and Time Results: Generator frequency, receive frequency, RTS/CTS delay, error-free seconds, percent error-free seconds, pattern loss seconds, test seconds, errored seconds, time and date.
Front-Panel Program Storage: Store and recall up to 10 sets of front-panel control and auxiliary function settings.
Auxiliary Functions: Over 14 programmable functions provide additional operational control.
Non-Volatile Memory: Stores current front-panel switch settings, 10 front-panel programs, three user-defined messages, and time and date of last power-down.
Winner will only receive the item (s) pictured above.
1 - Non-Functional Items: If the item you have received is defective, you can contact us within the warranty period. Defective item will be replaced if available, if not available a refund will be issued.
No walk-in return service provided.
In some occasions we accept returned merchandise with a 20% restocking fee.
Merchandise must be carefully packed and insured for the full purchase price with tracking number.
Returned items must not have any signs of abuse or intentional damage. Serial numbers are recorded.
Merchandise must be returned within 14 days after RMA has been issued in original packaging with packing slip.
When you contact us you need to provide support for your claim:
Computer component will not function:
Will require a diagnostic report or we need you to specify the problems you are experiencing.
Give description of the item you have received.
Will require photos of damages.
Describe the way received merchandise functions in comparison to how it should work.
Returns will be DENIED if any of the following apply:
You had item for 30 days or more or we have not received it within 14 days of RMA issue.
You didn't know of used condition, missing items not seen the the photo or incompatibility.
Needs items which were not included:
Batteries, AC Adapters, manuals, passwords, software or additional components needed for operation.
Marked, scratched or not as new.
Notify us with photos and we will contact the carrier and file a claim. See Policy #3.
4 - Freight Damages: If package arrives damaged, accept delivery and take photos of damaged area, then contact us so we can file a claim with the carrier. Refunds will be available after carriers reimbursement.
We do not claim responsibility in events of the example RMA situations below:
- For any losses in the mail while returning the DOA merchandise, we require proper tracking.
- If the returned merchandise is not properly packed and insured and is damaged during RMA return.
- When returns have signs of abuse or signs unit was disassembled. These items will be refused.
This item has been seen by alt people!

Contact: c-morris@parts-recycling.com (Carmela Morris) (email hidden).



Ttc acterna fireberd 4000 analyzer with option 4005